 **Midibox SEQ V4**  **Midibox SEQ V4** 
  
-Press the EXIT button, enter the CV configuration page, and select the AOUT_NG interface.+Press the EXIT button, ​use the scroll wheel to enter the CV configuration page, and select the AOUT_NG interface.
  
-This page also allows you to calibrate the CV outputs (volunteersplease add description ​for this process)+This page also allows you to calibrate the CV outputs. Select the AOUT channel you wish to calibrate ​(1-8) using the first encoder. Press the button underneath the Calibr. label and turn the encoder to select a calibration voltage. The options areMin/​Middle/​Max/​1V,​ 2V, 4V, 8V. Turn the encoder until the 1V is selected. Measure the voltage at the channel you are calibrating. It should equal 1V. If it doesn'​t,​ adjust the trimpot P1(for the first channeluntil the multimeter reads 1V. Follow the process for each voltage. It normally is not possible to get each voltage perfectly set. The goal is to get all of the voltages as close to the target as possible. 
 + 
 +Once the calibration is complete, turn the encoder until '​OFF'​ is showing. ​
  